PRODUCTS
- Autoclaves
- Baths & Circulators
- Chiller (Recirculating Cooler)
- Desiccators
- Environmental Chambers
- Temperature & Humidity Chamber Basic type (TH3-E)
- Temperature & Humidity Chamber Tabletop type (TH3-PE)
- Temperature & Humidity Chamber Tabletop type (TH3-ME)
- Temperature & Humidity Chamber Tabletop type (TH3-KE)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Fume Hoods
- Heating & Cooling Block
- Hotplate Stirrers & Stirrer
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate (Digital type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Heating Block (for Round Flask and Vial)
- Incubators
- Incubator, Air-jacket (Standard, IB4-AS)
- Incubator, Air-jacket (Advanced, IB4-AV)
- Incubator, Forced Convection (Standard, IB4-S)
- Incubator, Forced Convection (Advanced, IB4-V)
- Low Temperature Incubators (Forced Convection)
- Low Temp. Incubators (Air-jacketed)
- Low Temperature Incubator (Personal)
- Low Temperature Incubator (Multi type, Forced Convention)
- Incubated Shakers (Tabletop)
- Incubated Shakers (Floor)
- Incubated Shaker (Multi-Stackable)
- Incubated Shaker (Stackable)
- Incubator (Mini type, Forced Convention)
- Industrial Test Equipment
- Forced Convection Ovens (Large-General)
- Forced Convection Ovens (Program, OF3-P)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G Type)
- Chiller (Recirculating Coolers) (General)
- Chiller (Recirculating Coolers) (Low Temp. General)
- Chiller (Recirculating Coolers) (High Temp. Precision)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Mixers
- Vortex Mixer
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Shaker (Compact)
- Microplate Shaker
- Rocking Shaker
- Waving Shaker
- Heating Shaker
- Ovens
- Natural Convection Oven (Standard, ON4-S)
- Natural Convection Oven (Advanced, ON4-V)
- Vacuum Ovens
- Vacuum Ovens, OV4-S
- Forced Convection Ovens (Standard, OF4-S)
- Forced Convection Ovens (Advanced, OF4-V)
- Forced Convection Ovens (Program, OF4-P)
- Forced Convection Ovens (Program, OF3-P)
- Forced Convection Ovens (Large-General)
- Forced Convection Oven (Multi type, OF-02G-4C)
- Muffle Furnace
- Pumps
- Refrigerators & Freezers
- Rotator
- Special Purpose Chamber
- Shaker
- Storage
- Fire Safety Storage Cabinet (Type 90)
- Fire Safety Storage Cabinet (Type 30)
- Acid / Corrosive Cabinets
- Molded Acid Corrosive Cabinet
- Multipurpose Cabinet (Window Type)
- Gas Cylinder Cabinets
- Laboratory Refrigerators
- Filtering Storage Cabinets
- Filtering Storage Refrigerator
- Laboratory Freezers
- Vacuum Desiccators (Cubic)
- Vacuum Desiccators (Round)
- Vacuum Desiccators (Cylindrical)
- Desiccators (Cubic Models)
- Temperature Chambers
- Heating & Cooling Chamber Tabletop type (TC3-ME)
- Heating & Cooling Chamber Tabletop type (TC3-KE)
- Forced Convection Ovens (Large- Programmable)
- Forced Convection Ovens (Large-General)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G)
- Plastic ware & Others
- Safety Waste Disposal System
- Handle Beaker (Transparent / Translucent)
- Wash Bottle
- Power Supply for Electrophoresis System
- Ultrasonic Cleaners
- Electrophoresis Systems
- Magnetic Drives
- Disposable Beaker
- Plastic Beakers
- Tubing Connectors
- Carboys
- Flask Supports
- On-Ice Rack
- Tube Rack
- Storage Boxes
- Cryo Boxes
- Clamp Holders
- Software
Industrial Test Equipment
- HOME
- > PRODUCTS
- > Industrial Test Equipment
Industrial Test Equipment

- Autoclaves
- Baths & Circulators
- Chiller (Recirculating Cooler)
- Desiccators
- Environmental Chambers
- Temperature & Humidity Chamber Basic type (TH3-E)
- Temperature & Humidity Chamber Tabletop type (TH3-PE)
- Temperature & Humidity Chamber Tabletop type (TH3-ME)
- Temperature & Humidity Chamber Tabletop type (TH3-KE)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Fume Hoods
- Heating & Cooling Block
- Hotplate Stirrers & Stirrer
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate (Digital type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Heating Block (for Round Flask and Vial)
- Incubators
- Incubator, Air-jacket (Standard, IB4-AS)
- Incubator, Air-jacket (Advanced, IB4-AV)
- Incubator, Forced Convection (Standard, IB4-S)
- Incubator, Forced Convection (Advanced, IB4-V)
- Low Temperature Incubators (Forced Convection)
- Low Temp. Incubators (Air-jacketed)
- Low Temperature Incubator (Personal)
- Low Temperature Incubator (Multi type, Forced Convention)
- Incubated Shakers (Tabletop)
- Incubated Shakers (Floor)
- Incubated Shaker (Multi-Stackable)
- Incubated Shaker (Stackable)
- Incubator (Mini type, Forced Convention)
- Industrial Test Equipment
- Forced Convection Ovens (Large-General)
- Forced Convection Ovens (Program, OF3-P)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G Type)
- Chiller (Recirculating Coolers) (General)
- Chiller (Recirculating Coolers) (Low Temp. General)
- Chiller (Recirculating Coolers) (High Temp. Precision)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Mixers
- Vortex Mixer
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Shaker (Compact)
- Microplate Shaker
- Rocking Shaker
- Waving Shaker
- Heating Shaker
- Ovens
- Natural Convection Oven (Standard, ON4-S)
- Natural Convection Oven (Advanced, ON4-V)
- Vacuum Ovens
- Vacuum Ovens, OV4-S
- Forced Convection Ovens (Standard, OF4-S)
- Forced Convection Ovens (Advanced, OF4-V)
- Forced Convection Ovens (Program, OF4-P)
- Forced Convection Ovens (Program, OF3-P)
- Forced Convection Ovens (Large-General)
- Forced Convection Oven (Multi type, OF-02G-4C)
- Muffle Furnace
- Pumps
- Refrigerators & Freezers
- Rotator
- Special Purpose Chamber
- Shaker
- Storage
- Fire Safety Storage Cabinet (Type 90)
- Fire Safety Storage Cabinet (Type 30)
- Acid / Corrosive Cabinets
- Molded Acid Corrosive Cabinet
- Multipurpose Cabinet (Window Type)
- Gas Cylinder Cabinets
- Laboratory Refrigerators
- Filtering Storage Cabinets
- Filtering Storage Refrigerator
- Laboratory Freezers
- Vacuum Desiccators (Cubic)
- Vacuum Desiccators (Round)
- Vacuum Desiccators (Cylindrical)
- Desiccators (Cubic Models)
- Temperature Chambers
- Heating & Cooling Chamber Tabletop type (TC3-ME)
- Heating & Cooling Chamber Tabletop type (TC3-KE)
- Forced Convection Ovens (Large- Programmable)
- Forced Convection Ovens (Large-General)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G)
- Plastic ware & Others
- Safety Waste Disposal System
- Handle Beaker (Transparent / Translucent)
- Wash Bottle
- Power Supply for Electrophoresis System
- Ultrasonic Cleaners
- Electrophoresis Systems
- Magnetic Drives
- Disposable Beaker
- Plastic Beakers
- Tubing Connectors
- Carboys
- Flask Supports
- On-Ice Rack
- Tube Rack
- Storage Boxes
- Cryo Boxes
- Clamp Holders
- Software
Product Name | Temperature & Humidity Chambers (Floor Standing Models) | |||
---|---|---|---|---|
Model | TH-G | TH-I | TH-KH | |
Chamber volume (L) | 189, 302, 408, 800,1000, 1540 | 189, 302, 408 | 189, 302, 408 | |
Temp. control | Operating temp. range (℃/℉) | -40 to 150 / -40 to 302 | -40 to 150 / -40 to 302 | -70 to 150 / -94 to 302 |
Fluctuation (±℃/℉) | 0.3 / 0.54 at 40℃/75%RH | 0.3 / 0.54 at 40℃/75%RH | 0.3 / 0.54 at 40℃/75%RH | |
Variation (±℃/℉) | 0.5 / 0.9 at 40℃/75%RH | 0.5 / 0.9 at 40℃/75%RH | 0.5 / 0.9 at 40℃/75%RH | |
Humid. control | Operating humid. full range (%RH) | 25 to 95 | 20 to 95 | 25 to 95 |
Fluctuation (±%RH) | 0.4, 1.0, 2.0 at 75%RH/40℃ | 0.4at 75%RH/40℃ | 0.4at 75%RH/40℃ | |
Variation (±%RH) | 3.0at 75%RH/40℃ | 3.0at 75%RH/40℃ | 3.0at 75%RH/40℃ | |
Control | Timer | Wait on/off | Wait on/off | Wait on/off |
Auto-tuning | ![]() |
![]() |
![]() | |
Program function | ![]() |
![]() |
![]() | |
Computer interface | RS-232 port, RS-485 port (optional) |
RS-232 port, RS-485 port (optional) |
RS-232 port, RS-485 port (optional) | |
Safety | Over temp. limit | ![]() |
![]() |
![]() |
Door open alarm | ![]() |
![]() |
![]() | |
Over current limit | ![]() |
![]() |
![]() | |
Auto-run (power failure) | ![]() |
![]() |
![]() |
Product Name | Pharmaceutical Stability Test Chambers |
Clean Temp. & Humid. Chamber |
Plant Growth Chambers | |
---|---|---|---|---|
Model | TH-ICH | TH-CR | GC | |
Chamber volume (L) | 300, 760 | 270 | 300, 1000 | |
Temp. control | Operating temp. range (℃/℉) | -5 to 85 / 23 to 185 | -35 to 100 / -31 to 212 | 5 to 50 / 41 to 122 - Lamp off 10 to 50 / 50 to 122 - Lamp on |
Fluctuation (±℃/℉) | 0.3 / 0.54 at 40℃/60%RH | 0.5 / 0.9 at 40℃/60%RH | 0.1 / 0.18at 25℃ | |
Variation (±℃/℉) | 0.5, 0.7 / 0.9, 1.3 at 40℃/60%RH | 0.5 / 0.9at 40℃/60%RH | 0.8 / 1.43at 25℃ | |
Humid. control | Operating humid. full range(%RH) | 20 to 85 | 30 to 90 | 40 to 90 |
Fluctuation 1) (±%RH) | 3.0at 60%RH/40℃ | 3.0at 60%RH/40℃ | 3 at 60% RH | |
Variation 1) (±%RH) | 5.0at 60%RH/40℃ | 3.0at 60%RH/40℃ | - | |
Control | Timer | Wait on/off | Wait on/off | Wait on/off |
Auto-tuning | ![]() |
![]() |
![]() | |
Program function | ![]() |
![]() |
![]() | |
Computer interface | RS-232 port,RS-485 port (optional) | RS-232 port,RS-485 port (optional) | - | |
Safety | Over temp. limit | ![]() |
![]() |
![]() |
Door open alarm | ![]() |
![]() |
![]() | |
Over current limit | ![]() |
![]() |
![]() | |
Auto-run (power failure) | ![]() |
![]() |
![]() |
Temperature & Humidity Chambers (Floor Standing Models) |
Temperature & Humidity Chambers (Tabletop Models) | |||
---|---|---|---|---|
TH-TG | TH-KE | TH-ME | TH-PE | |
180, 314, 419 | 770, 997, 1540 | 25, 65, 100 | ||
-5 to 100 / 23 to 212 | -40 to 150 / -40 to 302 | -20 to 150 / -4 to 302 | 0 to 120 / 32 to 248 | |
0.3 / 0.54at 40℃/60%RH | 0.4, 0.3 / 0.72, 0.54 at 50℃/60%RH |
03, 0.2 / 0.54, 0.36 at 25℃/60%RH |
0.2, 0.3 / 0.36, 0.54 at 25℃/60%RH | |
0.5 / 0.9 at 40℃/60%RH | 0.3, 0.4 / 0.54, 0.72 at 50℃/60%RH |
0.6, 0.2 / 1.08, 0.36 at 25℃/60%RH |
0.3 / 0.54 at 25℃/60%RH | |
10 to 95 | 20 to 95 | 20 to 95 | 30 to 95 | |
2.0 at 60%RH/40℃ | 4.1, 2.8, 1.8 at 60%RH/50℃ |
2.0, 2.7 at 60%RH/55℃ |
1.6, 0.4, 0.5 at 60%RH/55℃ | |
3.0 at 60%RH/40℃ | 0.9, 1.0, 1.2 at 60%RH/50℃ |
0.6, 1.1, 1.2 at 60%RH/55℃ |
3.0 at 60%RH/55℃ | |
Wait on/off | Wait on/off | |||
![]() |
![]() | |||
![]() |
![]() | |||
RS-232 port, RS-485 port (optional) | RS-232 port, RS-485 port (optional) | |||
![]() |
![]() | |||
![]() |
![]() | |||
![]() |
![]() | |||
![]() |
![]() |
Product Name | Heating & Cooling Chambers(Floor Standing Models) | |||
---|---|---|---|---|
Model | KBD | KMV | JMV | |
Air flow | Horizontal airflow | Horizontal airflow | Vertical airflow | |
Chamber volume (L) | 125, 253, 420 | 125, 253, 420,720, 1000 | 125, 253, 420,720, 990 | |
Temp. control | Operating temp. range (℃/℉) | -70 to 180 / -94 to 356 | -35 to 180 / -31 to 356 | -35 to 180 / -31 to 356 |
Fluctuation at 100℃ (±℃/℉) | 0.2 / 0.36 | 0.4, 0.3, 0.2/ 0.72, 0.54, 0.36 | 0.5, 0.3, 0.4/ 0.9, 0.54, 0.72 | |
Variation at 100℃(±℃/℉) | 1.2, 1.0 / 2.16, 1.8 | 1.0, 0.9 / 1.8, 1.62 | 1.0, 0.8, 1.2, 0.9/ 1.8, 1.44, 2.16, 1.62 | |
Control | Timer | Wait on/off | Wait on/off | Wait on/off |
Auto-tuning | ![]() |
![]() |
![]() | |
Program function | ![]() |
![]() |
![]() | |
Computer interface | RS-232 port, RS-485 port (optional) |
RS-232 port, RS-485 port (optional) |
RS-232 port, RS-485 port (optional) | |
Safety | Over temp. limit | ![]() |
![]() |
![]() |
Door open alarm | ![]() |
![]() |
![]() | |
Over current limit | ![]() |
![]() |
![]() | |
Auto-run (power failure) | ![]() |
![]() |
![]() |
Product Name | Heating Chambers(Floor Standing Models) | ||
---|---|---|---|
Model | LBV | LTV | |
Air flow | Horizontal airflow | Horizontal airflow | |
Chamber volume (L) | 125, 253, 420, 720, 1000 | 125, 253, 420, 720, 1000 | |
Temp. control | Operating temp. range (℃/℉) | Amb. +45 to 250/ Amb. +81 to 482 | Amb. +45 to 350/ Amb. +81 to 662 |
Fluctuation at 100℃ (±℃/℉) | 0.3 / 0.54 | 0.4, 0.3, 0.5/ 0.72, 0.54, 0.90 | |
Variation at 100℃ (±℃/℉) | 0.4, 1.3, 0.5/ 0.72, 2.34, 0.9 | 0.5, 0.6, 0.7, 0.4/ 0.9, 1.08, 1.26, 0.72 | |
Control | Timer | Wait on/off | Wait on/off |
Auto-tuning | ![]() |
![]() | |
Program function | ![]() |
![]() | |
Computer interface | RS-232 port, RS-485 port (optional) | RS-232 port, RS-485 port (optional) | |
Safety | Over temp. limit | ![]() |
![]() |
Door open alarm | ![]() |
![]() | |
Over current limit | ![]() |
![]() | |
Auto-run (power failure) | ![]() |
![]() |
Heating & Cooling Chambers(Floor Standing Models) | Heating & Cooling Chambers(Tabletop Models) | ||||
---|---|---|---|---|---|
PBV | PMV | LCH / LCH-G | LCH-2C / LCH-G-2C | TC-KE | TC-ME |
Horizontal airflow | Horizontal airflow | Horizontal airflow | Vertical airflow | ||
125, 250, 400, 700, 1000 |
125, 250, 400, 700, 1000 |
-20 to 100 / -4 to 212 (LCH / LCH-G), 0 to 100 / 32 to 212 (LCH-2C / LCH-G-2C) |
-40 to 150 / -40 to 302 |
-20 to 120 / -4 to 248 | |
0.3, 0.4, 0.2 / 0.54, 0.72, 0.36 |
0.3 / 0.54 | 0.3 / 0.54 | 0.5 / 0.9 at 50℃ | 0.4, 0.3 / 2.0, 1.9 | |
0.6, 0.7, 0.8 / 1.08, 1.26, 1.44 |
1.0, 0.8, 0.7 / 1.8, 1.44, 1.26 |
0.8 / 1.44 at 80℃ | 1.0 / 1.8 at 50℃ | 2.0, 1.9, 1.8 / 3.6, 3.42, 3.24 | |
Wait on/off | Wait on/off | Wait on/off | Wait on/off | ||
![]() |
![]() |
![]() |
![]() | ||
![]() |
![]() |
![]() |
![]() | ||
RS-232 port, RS-485 port (optional) |
RS-232 port, RS-485 port (optional) |
RS-232 port | RS-232 port, RS-485 port (optional) | ||
![]() |
![]() |
![]() |
![]() | ||
![]() |
![]() |
![]() |
![]() | ||
![]() |
![]() |
![]() |
![]() | ||
![]() |
![]() |
![]() |
![]() |