产品
- 灭菌锅(Autoclaves)
- 恒温水浴&循环浴槽(Baths & Circulators)
- 防潮箱(Desiccators)
- 恒温恒湿环境箱(Environmental Chambers)
- 旋转式混匀仪(Rotator)
- 通风柜(Fume Hoods)
- 干浴器/金属浴(Heating & Cooling Block)
- 加热磁力搅拌器(Hotplate Stirrers)
- 培养箱(Incubators)
- 搅拌器(Mixers)
- 烘箱(Oven)
- 泵(Pumps)
- 摇床(Shakers)
- 温度试验箱(Temperature Chambers)
- 冷却水循环装置(Recirculating Coolers)
- 冷藏箱 & 低温保存箱(Refrigerators & Freezers)
- 恒温恒湿环境箱(Special Purpose Chamber)
- 储藏柜(Storage)
- 工业设备(Industrial Test Equipment)
- 高低温试验箱 桌上型 (TC3-KE)
- 高低温试验箱 桌上型 (TC3-ME)
- 恒温恒湿试验箱 桌上型 (TH3-KE)
- 恒温恒湿试验箱 桌上型((TH3-ME)
- 恒温恒湿试验箱 桌上型(TH3-PE)
- 恒温恒湿试验箱 Economic type (TH3-E)
- 强制对流烘箱 (编程型)
- 强制对流烘箱 (通用型)
- 洁净型干燥箱-100级 (General)
- 洁净型干燥箱-100级 (Programmable)
- 高温试验箱 (落地型 - LBV )
- 高温试验箱 (落地型 - LTV)
- 高低温试验箱 (落地型 - KBD)
- 高低温试验箱 (落地型 - KMV)
- 高低温试验箱 (落地型 - JMV)
- 高低温试验箱 (落地型 - PBV)
- 高低温试验箱 (落地型 - PMV)
- 高低温试验箱 (落地型 - LCH)
- 高低温试验箱 (落地型 - LCH-G)
- 冷却水循环装置 (通用型)
- 冷却水循环装置 (低温型)
- 冷却水循环装置 (高端低温型)
- 冷却水循环装置 (高温型)
- 恒温恒湿环境箱 (TH-G)
- 恒温恒湿环境箱 (TH-KH)
- 恒温恒湿环境箱 (TH-TG)
- 药品稳定测试试验箱 (TH-ICH)
- 洁净型恒温恒湿箱(TH-CR)
- 植物生长箱 (GC)
- 塑料器皿 & 其它(Plastic ware)
- LC GreenBox
Baths & Circulators
- HOME
- > 产品
- > Baths & Circulators
- 灭菌锅(Autoclaves)
- 恒温水浴&循环浴槽(Baths & Circulators)
- 防潮箱(Desiccators)
- 恒温恒湿环境箱(Environmental Chambers)
- 旋转式混匀仪(Rotator)
- 通风柜(Fume Hoods)
- 干浴器/金属浴(Heating & Cooling Block)
- 加热磁力搅拌器(Hotplate Stirrers)
- 培养箱(Incubators)
- 搅拌器(Mixers)
- 烘箱(Oven)
- 泵(Pumps)
- 摇床(Shakers)
- 温度试验箱(Temperature Chambers)
- 冷却水循环装置(Recirculating Coolers)
- 冷藏箱 & 低温保存箱(Refrigerators & Freezers)
- 恒温恒湿环境箱(Special Purpose Chamber)
- 储藏柜(Storage)
- 工业设备(Industrial Test Equipment)
- 高低温试验箱 桌上型 (TC3-KE)
- 高低温试验箱 桌上型 (TC3-ME)
- 恒温恒湿试验箱 桌上型 (TH3-KE)
- 恒温恒湿试验箱 桌上型((TH3-ME)
- 恒温恒湿试验箱 桌上型(TH3-PE)
- 恒温恒湿试验箱 Economic type (TH3-E)
- 强制对流烘箱 (编程型)
- 强制对流烘箱 (通用型)
- 洁净型干燥箱-100级 (General)
- 洁净型干燥箱-100级 (Programmable)
- 高温试验箱 (落地型 - LBV )
- 高温试验箱 (落地型 - LTV)
- 高低温试验箱 (落地型 - KBD)
- 高低温试验箱 (落地型 - KMV)
- 高低温试验箱 (落地型 - JMV)
- 高低温试验箱 (落地型 - PBV)
- 高低温试验箱 (落地型 - PMV)
- 高低温试验箱 (落地型 - LCH)
- 高低温试验箱 (落地型 - LCH-G)
- 冷却水循环装置 (通用型)
- 冷却水循环装置 (低温型)
- 冷却水循环装置 (高端低温型)
- 冷却水循环装置 (高温型)
- 恒温恒湿环境箱 (TH-G)
- 恒温恒湿环境箱 (TH-KH)
- 恒温恒湿环境箱 (TH-TG)
- 药品稳定测试试验箱 (TH-ICH)
- 洁净型恒温恒湿箱(TH-CR)
- 植物生长箱 (GC)
- 塑料器皿 & 其它(Plastic ware)
- LC GreenBox
Performance
- Temperature range from ambient +5°Cto 150°C.
- Microprocessor PID control / Automatic tuning / Calibration.
- Optimal temperature equilibrium achieved by a vane type stirrer with strong circulation power.
Convenience
- Easy readout digital LED displays.
(0.01°Cresolution at 0 to 99.9°C/ 0.1°C resolution at 100 to 150°C) - Dual wait on/off timer modes. (1 min. to 99 hr. 59 min.)
- Convenient memory function of up to three frequently set temperature.
- Clear visibility provided by double tempered safety glass windows in front and rear sides.
(for operation from 10°C, use an optional cooling circulator) - Ø 51mm holes (for glass capillary viscometer tubes) and a Ø12.6 mm hole. (for a thermometer)
- RS-232 interface for external control and data collection.
- Monitor via mobile app anytime, anywhere with LC Connected (mobile monitoring system) connection. (when purchased LC GreenBox)
Safety
- Isolated design of agitator, heater, and sensor by a baffle plate to minimize the turbulence in the bath fluid and also to protect users and samples against direct contact.
- Complete safety protection system with warning alarms.
- Low fluid level and dry-running, over-temperature, over-current.
-
Ideal for application requiring high visibility
-
Easy holding of U-shaped viscometer glass tubes (optional)
Model | VB-25G | VB-40G | |||
---|---|---|---|---|---|
Bath volume (L / cu ft) |
25 / 0.9 |
40 / 1.4 |
|||
Temperature |
Working temperature range (℃ / ℉) |
Amb. +5 to 150 / Amb. +9 to 302 |
|||
Temperature stability at 50℃ (±℃ / ℉) |
0.1 / 0.18 |
0.1 / 0.18 |
|||
Heat up time to 70℃ (min) (±℃ / ℉) |
35 |
55 |
|||
Dimension |
Bath opening / depth (W×L, D) (mm / inch) |
145×265, 330 / 5.7×10.4, 13 |
295×265, 330 / 11.6×10.4, 13 |
||
Cover lids / Hole for thermometer (mm) |
5ea / Ø51, 1ea / Ø12.6 |
8ea / Ø51, 1ea / Ø12.6 |
|||
Exterior (W×L×H) (mm / inch) |
492×374×536 / 19.4×14.7×21.1 |
642×374×536 / 25.3×14.7×21.1 |
|||
Net weight (kg / lbs) |
28 / 61.7 |
37 / 81.6 |
|||
Electrical requirements (230V) |
60Hz, 13A | 50Hz, 13A | 60Hz, 13A | 50Hz, 13A | |
Cat. No. |
AAH43302K | AAH43302K | AAH43402K | AAH43402K |
※ The lowest temperature that can be controlled depends on changes in room temperature and sample temperature.Therefore, please contact the distributor of our products before purchasing for technical consultation.
Viscometer tube holders
Specially designed to hold a two-opening viscometer glass tube and made of Bakelite, renowned for its high thermal endurance.
Cat. No. | Suitable for |
---|---|
AAA43501 | VB-25G (need max. 5 holders) |
VB-40G (need max. 8 holders) |
Cooling circulators
The temperature range of viscometer heating baths can be lowered up to +10°C (+50°F) when used with an optional cooling circulator.
Cat. No. | Description | Suitable for |
---|---|---|
AAH57051K | RW3-1025 (230V, 60Hz) | VB-25G (230V, 60Hz) |
AAH57651K | RW3-1025P (230V, 60Hz) | |
AAH57052K | RW3-1025 (230V, 50Hz) | VB-25G (230V, 50Hz) |
AAH57652K | RW3-1025P (230V, 50Hz) | |
AAH57061K | RW3-2025 (230V, 60Hz) | VB-40G (230V, 60Hz) |
AAH57661K | RW3-2025P (230V, 60Hz) | |
AAH57062K | RW3-2025 (230V, 50Hz) | VB-40G (230V, 50Hz) |
AAH57662K | RW3-2025P (230V, 50Hz) |
* More information on the cooling circulators.
LC GreenBox
Real-time monitoring and control of device operation via mobile app.
Up to 4 devices can be connected at once.
Cat. No. | Description |
---|---|
AAHQ1011K | JGW-4 |