PRODUCTS
- Autoclaves
- Baths & Circulators
- Chiller (Recirculating Cooler)
- Desiccators
- Environmental Chambers
- Temperature & Humidity Chamber Basic type (TH3-E)
- Temperature & Humidity Chamber Tabletop type (TH3-PE)
- Temperature & Humidity Chamber Tabletop type (TH3-ME)
- Temperature & Humidity Chamber Tabletop type (TH3-KE)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Fume Hoods
- Heating & Cooling Block
- Hotplate Stirrers & Stirrer
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate (Digital type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Heating Block (for Round Flask and Vial)
- Incubators
- Incubators (General, Air-jacket)
- Incubators (Film Heater, Economy)
- Incubators (Multi type Forced Convention)
- Low Temperature Incubators (Forced Convection)
- Low Temp. Incubators (Air-jacketed)
- Low Temperature Incubator (Personal)
- Low Temperature Incubator (Multi type, Forced Convention)
- Incubated Shakers (Tabletop)
- Incubated Shakers (Floor)
- Incubated Shaker (Multi-Stackable)
- Incubated Shaker (Stackable)
- Incubator (Mini type, Forced Convention)
- Industrial Test Equipment
- Forced Convection Ovens (Large-General)
- Forced Convection Ovens (Program, OF3-P)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G Type)
- Chiller (Recirculating Coolers) (General)
- Chiller (Recirculating Coolers) (Low Temp. General)
- Chiller (Recirculating Coolers) (High Temp. Precision)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Mixers
- Vortex Mixer
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Shaker (Compact)
- Microplate Shaker
- Rocking Shaker
- Waving Shaker
- Heating Shaker
- Ovens
- Vacuum Ovens
- Vacuum Ovens, OV4-S
- Forced Convection Ovens (Standard, OF4-S)
- Forced Convection Ovens (Advanced, OF4-V)
- Forced Convection Ovens (Program, OF4-P)
- Forced Convection Ovens (Program, OF3-P)
- Forced Convection Ovens (Large-General)
- Forced Convection Oven (Multi type, OF-02G-4C)
- Natural Convection Ovens (General, ON)
- Natural Convection Ovens (Economy)
- Muffle Furnace
- Pumps
- Refrigerators & Freezers
- Rotator
- Special Purpose Chamber
- Shaker
- Storage
- Fire Safety Storage Cabinet (Type 90)
- Fire Safety Storage Cabinet (Type 30)
- Acid / Corrosive Cabinets
- Molded Acid Corrosive Cabinet
- Multipurpose Cabinet (Window Type)
- Gas Cylinder Cabinets
- Laboratory Refrigerators
- Filtering Storage Cabinets
- Filtering Storage Refrigerator
- Laboratory Freezers
- Vacuum Desiccators (Cubic)
- Vacuum Desiccators (Round)
- Vacuum Desiccators (Cylindrical)
- Desiccators (Cubic Models)
- Temperature Chambers
- Heating & Cooling Chamber Tabletop type (TC3-ME)
- Heating & Cooling Chamber Tabletop type (TC3-KE)
- Forced Convection Ovens (Large- Programmable)
- Forced Convection Ovens (Large-General)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G)
- Plastic ware & Others
- Safety Waste Disposal System
- Handle Beaker (Transparent / Translucent)
- Wash Bottle
- Power Supply for Electrophoresis System
- Ultrasonic Cleaners
- Electrophoresis Systems
- Magnetic Drives
- Disposable Beaker
- Plastic Beakers
- Tubing Connectors
- Carboys
- Flask Supports
- On-Ice Rack
- Tube Rack
- Storage Boxes
- Cryo Boxes
- Clamp Holders
- Software
储藏柜(Storage)
- HOME
- > PRODUCTS
- > 储藏柜(Storage)
储藏柜(Storage)
- Autoclaves
- Baths & Circulators
- Chiller (Recirculating Cooler)
- Desiccators
- Environmental Chambers
- Temperature & Humidity Chamber Basic type (TH3-E)
- Temperature & Humidity Chamber Tabletop type (TH3-PE)
- Temperature & Humidity Chamber Tabletop type (TH3-ME)
- Temperature & Humidity Chamber Tabletop type (TH3-KE)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Fume Hoods
- Heating & Cooling Block
- Hotplate Stirrers & Stirrer
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate (Digital type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Heating Block (for Round Flask and Vial)
- Incubators
- Incubators (General, Air-jacket)
- Incubators (Film Heater, Economy)
- Incubators (Multi type Forced Convention)
- Low Temperature Incubators (Forced Convection)
- Low Temp. Incubators (Air-jacketed)
- Low Temperature Incubator (Personal)
- Low Temperature Incubator (Multi type, Forced Convention)
- Incubated Shakers (Tabletop)
- Incubated Shakers (Floor)
- Incubated Shaker (Multi-Stackable)
- Incubated Shaker (Stackable)
- Incubator (Mini type, Forced Convention)
- Industrial Test Equipment
- Forced Convection Ovens (Large-General)
- Forced Convection Ovens (Program, OF3-P)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G Type)
- Chiller (Recirculating Coolers) (General)
- Chiller (Recirculating Coolers) (Low Temp. General)
- Chiller (Recirculating Coolers) (High Temp. Precision)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Mixers
- Vortex Mixer
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Shaker (Compact)
- Microplate Shaker
- Rocking Shaker
- Waving Shaker
- Heating Shaker
- Ovens
- Vacuum Ovens
- Vacuum Ovens, OV4-S
- Forced Convection Ovens (Standard, OF4-S)
- Forced Convection Ovens (Advanced, OF4-V)
- Forced Convection Ovens (Program, OF4-P)
- Forced Convection Ovens (Program, OF3-P)
- Forced Convection Ovens (Large-General)
- Forced Convection Oven (Multi type, OF-02G-4C)
- Natural Convection Ovens (General, ON)
- Natural Convection Ovens (Economy)
- Muffle Furnace
- Pumps
- Refrigerators & Freezers
- Rotator
- Special Purpose Chamber
- Shaker
- Storage
- Fire Safety Storage Cabinet (Type 90)
- Fire Safety Storage Cabinet (Type 30)
- Acid / Corrosive Cabinets
- Molded Acid Corrosive Cabinet
- Multipurpose Cabinet (Window Type)
- Gas Cylinder Cabinets
- Laboratory Refrigerators
- Filtering Storage Cabinets
- Filtering Storage Refrigerator
- Laboratory Freezers
- Vacuum Desiccators (Cubic)
- Vacuum Desiccators (Round)
- Vacuum Desiccators (Cylindrical)
- Desiccators (Cubic Models)
- Temperature Chambers
- Heating & Cooling Chamber Tabletop type (TC3-ME)
- Heating & Cooling Chamber Tabletop type (TC3-KE)
- Forced Convection Ovens (Large- Programmable)
- Forced Convection Ovens (Large-General)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G)
- Plastic ware & Others
- Safety Waste Disposal System
- Handle Beaker (Transparent / Translucent)
- Wash Bottle
- Power Supply for Electrophoresis System
- Ultrasonic Cleaners
- Electrophoresis Systems
- Magnetic Drives
- Disposable Beaker
- Plastic Beakers
- Tubing Connectors
- Carboys
- Flask Supports
- On-Ice Rack
- Tube Rack
- Storage Boxes
- Cryo Boxes
- Clamp Holders
- Software
60 分钟防火系列
类型 | 型号 |
---|---|
落地型 | SC2-60F-0806D1-CL |
SC2-60F-0806D1-CR | |
SC2-60F-0706D1-C |
防火安全柜
- 强大的防火性能
防火性能符合欧洲最严格的标准, 在火灾状况下内部温度保持在180K以下,最多可维持90分钟。 - 火灾反应密闭系统
当温度达到50℃,门会自动关闭, 室内温度达到70±10°C时,排气口及换气口自动封闭, 发生火灾时完全切断外部热气进入内部。 - 根据用户用途选择合适的型号
根据需要处理危险物品的燃点,能够扑灭火灾, 来预测时间等因素选择型号。 - 内部材质具有耐化学性
内部喷涂多酚树脂,即使长时间使用,也具有良好的抗化学性。 - 桌下型系列高度可选择 (SC3桌下型系列)
安装通风柜下端时, 考虑作业高度,可选择730mm/820mm的高度。
坚固安全的搁板结构
- 坚固的搁板结构
每个搁板最多承载80kg的重量, 可牢牢固定在内部左右壁面。 - 安全的搁板设计
搁板30mm深的保护边缘,便于安全储存,即使储存物泄露也能保证安全。 - 选择合适的搁板
标配的搁板采用环氧分体涂装材质,耐化学性强, 亦可选择不锈钢货架或者PP材质托盘。(选配)
防火性能经过验证!
项目测试验证
- 30分钟/60分钟/90分钟防火性能测试。
- 根据EN1363-1标准进行火灾试验时,将AT维持在180°C以下的时间,即为防火合格。(EN-14470-1)
方便取放试剂
配有门关闭系统,门可停留在特定的位置,方便拿取易燃试剂。
自动密封换气口
周边火灾时,当周围温度达到70±10°C时, 排气口及换气口将自动密封, 完全阻断外部热气进入内部。
防静电接地
接地可以防止内部的易燃蒸汽由于意外的电火花,从而发生事故。
正确的安装是每个搁板都需要连接到内部的汇电板。
而且导电螺丝(位于柜体后部上方)也需要和分布控制板连接。
(为了防止接地线没有与分布控制板连接,请使用接地插座。(选配)
正确的安装是每个搁板都需要连接到内部的汇电板。
而且导电螺丝(位于柜体后部上方)也需要和分布控制板连接。
(为了防止接地线没有与分布控制板连接,请使用接地插座。(选配)
易燃蒸汽安全通风
通过吸气口和排气口可以顺利排出气体, 预防蒸汽累积引发安全事故, 保护试验者的呼吸器官。
可与实验室安全工作台组合使用
放置于通风柜及实验台下部, 在储藏危险物及废液方面具有卓越效果。
-
废液集水槽
当储存物意外泄漏时,防止废液流出柜体,安全便利。 -
门锁装置
标配和钥匙,防止未经授权的访问。 -
安全储存物品
符合人体工程学的结构,方便使用者使用搁板,安全方便。
-
便于移动和安装
叉车空间便于移动,高度可调便于安装。 -
抽滤模块 (选配)
无需另外连接导管,即可将储藏柜内部的 易燃气体用碳过滤器过滤。 -
选择合适的搁板
落地型防火柜标配3块搁板(最大承载80kg)(选配)
EN 14470-1 | NFPA 30 | |
---|---|---|
防火性能 | 0 | 0 |
根据EN 1363-1标准进行火灾测试, 15 分钟- 90 分钟。 (15 分钟 / 30 分钟 / 60 分钟 / 90 分钟) | 根据NFPA 251标准进行火灾测试,10分钟标准。 | |
易燃气体外排 | 0 | X |
建议气体外排排气时检查储藏柜内部声压的形成 | 不建议外排。(建议使用NFPA 30指定标准的容器) | |
将易燃气体的浓度保持在LEL (爆炸下限)以下,并通过通风来去除异味。 |
通风口密封,储藏柜内部发生恶臭。 | |
火灾侦测,自动门和换气口关闭 | 0 | X |
火灾试验时,在打开通风口的情况下进行试验。 | 火灾试验时,在堵住通风口的情况下进行试验。 与外部通风设施连接时, 未考虑到火灾安全。 |
EN14470-1标准与NFPA30国际标准的比较
Specification (Type 60)
型号 | SC2-60F-0806D1-CL SC2-60F-0806D1-CR |
SC2-60F-0706D1-C |
---|---|---|
内部容积 (L / cu ft) | 89 / 3.1 | 76 / 2.7 |
内部尺寸 (W x D x H, mm / inch) | 505 x 419 x 422 / 19.9 x 16.5 x 16.6 |
505 x 419 x 362 / 19.9 x 16.5 x 14.3 |
外部尺寸 (W x D x H, mm / inch) | 600 x 610 x 820 / 23.6 x 24.0 x 32.3 |
600 x 610 x 720 / 23.6 x 24.0 x 28.3 |
最大承载重量 (kg / lbs) | 80 / 176.4 | 80 / 176.4 |
底部集水槽1) (容积 : L / cu ft) | 7 / 0.25 | 7 / 0.25 |
净重 (kg / lbs) | 106 / 233.7 | 100 / 220.5 |
货号 | AAAF360310 AAAF360311 |
AAAF360110 |
产品外观 | ||
产品内部 |
1) 提2-供60环F氧-0粉81末2D喷2涂底部集水槽(S标C2配-6),F-可08更09换D成2不锈钢材质S。C(2选-6配)
选配件 (Type 60)
选配件 | 描述 (W x D x H, mm / inch) | SC2-60F-0806D1-CL / SC2-60F-0806D1-CR | SC2-60F-0706D1-C |
---|---|---|---|
基座(侧面) | 480 x 340 x 350 / 18.9 x 13.4 x 13.8 | AAAF15364 | AAAF15364 |
抽虑模块 (EM-33) (230V, 60Hz) | 348 x 498 x 343 / 13.7 x 19.6 x 13.5 | AAAF1536 | AAAF1536 |
尺寸 (单位: mm / inch))
型号 | A | B | C1) | D (直径) | |
---|---|---|---|---|---|
桌下型 (门) | SC2-60F-0806D1-CR/CL | 125 / 4.9 | 530 / 20.9 | 1070 / 42.1 | 102 / 4.0 |
SC2-60F-0706D1-C | 125 / 4.9 | 480 / 18.9 | 1070 / 42.1 | 102 / 4.0 | |
桌下型 (抽屉) | SC3-30F-0812D2D-C | 160 / 6.3 | 235 / 9.3 | 840 / 33.1 | 60 / 2.4 |
SC3-30F-0806D1D-C | 160 / 6.3 | 235 / 9.3 | 840 / 33.1 | 60 / 2.4 | |
较高型 | SC3-30F-1912D2-C | 180 / 7.1 | 170 / 6.7 | 1095 / 43.1 | 76 / 3.0 |
SC3-30F-1906D2-C | 180 / 7.1 | 170 / 6.7 | 1120 / 44.1 | 76 / 3.0 |
1) C is the maximum depth when the door is opened.