바로가기 메뉴
컨텐츠바로가기
주메뉴바로가기
하단메뉴바로가기

PRODUCTS

Temperature Chambers

  • HOME
  • > PRODUCTS
  • > Temperature Chambers
Temperature Chambers
Product Name Heating & Cooling Chambers(Floor Standing Models)
Model KBD KMV JMV
Air flow Horizontal airflow Horizontal airflow Vertical airflow
Chamber volume (L) 125, 253, 420 125, 253, 420,720, 1000 125, 253, 420,720, 990
Temp. control Operating temp. range (℃/℉) -70 to 180 / -94 to 356 -35 to 180 / -31 to 356 -35 to 180 / -31 to 356
Fluctuation at 100℃ (±℃/℉) 0.2 / 0.36 0.4, 0.3, 0.2/ 0.72, 0.54, 0.36 0.5, 0.3, 0.4/ 0.9, 0.54, 0.72
Variation at 100℃ (±℃/℉) 1.2, 1.0 / 2.16, 1.8 1.0, 0.9  / 1.8, 1.62 1.0, 0.8, 1.2, 0.9/ 1.8, 1.44, 2.16, 1.62
Control Timer Wait on/off Wait on/off Wait on/off
Auto-tuning
Program function
Computer interface RS-232 port,
RS-485 port (optional)
RS-232 port,
RS-485 port (optional)
RS-232 port,
RS-485 port (optional)
Safety Over temp. limit
Door open alarm
Over current limit
Auto-run (power failure)
Product Name Heating Chambers(Floor Standing Models)
Model LBV LTV
Air flow Horizontal airflow Horizontal airflow
Chamber volume (L) 125, 253, 420, 720, 1000 125, 253, 420, 720, 1000
Temp. control Operating temp. range (℃/℉) Amb. +45 to 250/ Amb. +81 to 482 Amb. +45 to 350/ Amb. +81 to 662
Fluctuation at 100℃ (±℃/℉) 0.3 / 0.54 0.4, 0.3, 0.5/ 0.72, 0.54, 0.90
Variation at 100℃ (±℃/℉) 0.4, 1.3, 0.5/ 0.72, 2.34, 0.9 0.5, 0.6, 0.7, 0.4/ 0.9, 1.08, 1.26, 0.72
Control Timer Wait on/off Wait on/off
Auto-tuning
Program function
Computer interface RS-232 port, RS-485 port (optional) RS-232 port, RS-485 port (optional)
Safety Over temp. limit
Door open alarm
Over current limit
Auto-run (power failure)
Product Name Heating & Cooling Chambers(Floor Standing Models)
Model PBV PMV LCH / LCH-G LCH-2C / LCH-G-2C
Air flow Horizontal airflow Horizontal airflow Horizontal airflow
Chamber volume (L) 125, 250, 400, 700, 1000 125, 250, 400, 700, 1000 150, 255, 485 150 x 2 chambers
Temp. control Operating temp. range (℃/℉) -25 to 100 / -13 to 212 -5 to 100 / 23 to 212 -20 to 100 / -4 to 212 (LCH / LCH-G) 0 to 100 / 32 to 212 (LCH-2C / LCH-G-2C)
Fluctuation at 100℃ (±℃/℉) 0.3, 0.4, 0.2 / 0.54, 0.72, 0.36 0.3 / 0.54 0.3 / 0.54
Variation at 100℃
(±℃/℉)
0.6, 0.7, 0.8 / 1.08, 1.26, 1.44 1.0, 0.8, 0.7 / 1.8, 1.44, 1.26 0.8 / 1.44 at 80℃
Control Timer Wait on/off Wait on/off Wait on/off
Auto-tuning
Program function
Computer interface RS-232 port, RS-485 port (optional) RS-232 port, RS-485 port (optional) RS-232 port
Safety Over temp. limit
Door open alarm
Over current limit
Auto-run (power failure)
Product Name Heating & Cooling Chambers
(Tabletop Models)
Model TC-KE TC-ME
Air flow Vertical airflow
Chamber volume (L) 25, 65, 100
Temp. control Operating temp. range (℃/℉) -40 to 150 / -40 to 302 -20 to 120 / -4 to 248
Fluctuation at 100℃ (±℃/℉) 0.5 / 0.9 at 50℃ 0.4, 0.3 / 2.0, 1.9
Variation at 100℃
(±℃/℉)
1.0 / 1.8 at 50℃ 2.0, 1.9, 1.8 / 3.6, 3.42, 3.24
Control Timer Wait on/off
Auto-tuning
Program function
Computer interface RS-232 port, RS-485 port (optional)
Safety Over temp. limit
Door open alarm
Over current limit
Auto-run (power failure)