바로가기 메뉴
컨텐츠바로가기
주메뉴바로가기
하단메뉴바로가기

PRODUCTS

Special Purpose Chamber

  • HOME
  • > PRODUCTS
  • > Special Purpose Chamber
Special Purpose Chamber

Pharmaceutical Stability Test Chamber

Manufactured in accordance with ICH Guidelines Q1A-Stability test (R2), Q1B-Photostability test (Option 2).

Model Name : TH-ICH-300/800


Control range

  • Temperature range from 0 to 120°C Humidity range from 30 to 95% RH

Performance

  • Microprocessor PID control / Temperature calibration / Automatic tuning.
  • Rapid humidity control is achieved by adapting the humidification tank interior to the chamber.
  • Air-tight door closure with perfect sealed packing.
    - Heat-resistant silicone packing completely blocks high heat leakage from the inner chamber.

Convenience

  • Two different sized models available to suit any users’ needs.
  • Corrosion resistant stainless steel chamber.
  • Cable port for introduction of external probes or wires.
    - 50mm diameter cable port comes standard on the left side of the unit.
    - Additional 50mm or 80mm diameter cable ports, custom ordered. (optional)
  • Inner glass door with entry ports for handling samples without affecting inner chamber temperature and humidity. (optional)
  • Casters for easy mobility during installation or relocation.
  • User friendly LCD controller.
    - Colorful interactive touch type LCD controller.
    - Set point temperature and present temperature are clearly shown together on display.
    - Sufficient programmable control support.
    - Operating progress can be shown in graph mode for better data understanding.
    - Automatic start/stop can be programmed for unattended operations.
    - Display indicates abnormal temperature changes or power failures.
    - Selective bilingual language support.
    (Korean / English or English / Chinese, selectable only when placing an order)
    - Temperature and other operating parameters can be recorded using a six channel digital recorder.(optional)
  • Computer interface.
    - RS-485 communication port (optional) enables connection up to maximum 32 units. Simultaneous monitoring and operating of multiple units is an available feature.
    - Program patterns are simple to set with the use of our software.
    - Easy to check status of real-time operations. Graph data supports easy understanding.
    - Storage and documentation of programs.
    - Data with saving capabilities in excel and text format.
    - Storage of program information, backup of value settings, recovery, and temperature values.
    - RS-232 communication port as standard offer.
Description No
Programmable pattern capacity 100
Pattern repeat time 999
Part repeat time 255
Max. segments per a pattern 100
Available max. segments* 2000
Programmable process time per a segment 0 to 99 hr. 59 min.

* Even though the max. segments per pattern are 100, the total available segments are up to 6000 not 10000, therefore arrangement of the number of segment and patterns will need to be done properly.

Stability test ICH guideline Q1A (R2)

  • Operating progress visible through graph mode for better data analyzation.
  • Cyclic defrost system, designed to work excellently for the long period stability test operation. (※Temperature and humidity changes may occur during automatic defrost.)
  • Maintenance of water supply are easily performed with a front water tank.
    - Water level check indicated by water level bar in the tank.
  • Water supply during operation is also available for long term test purposes.
  • Direct water system provides user great convenience when performing long-term test. (optional)

Photostability test ICH guidelineQ1B (Option 2)

  • Built in UV and fluorescent lamps for uniformed luminescence.
  • Equipped with movable UV and VIS sensors .
  • Independent lamp controller
    - An indicator for Total usage time of UV and fluorescent lamps.
  • Convenient set function of cumulative dosage and lamp Of

Safety

  • Built in door lock with a key.
  • Automatic shut off after overheat alarm.
  • Low and empty water level alarm.
  • Power supply leakage breaker.
  • Over current protection.
  • Open door alarm.
  • Lamp controller

  • TH-KEMEPE display-1.jpg

    LCD controller

  • Digital recorder (optional)

  • Water level indicator

     
Model TH-ICH-300 TH-ICH-800
Chamber volume (L / cu ft) 300 / 10.6 760 / 26.8
Controller PID control (LCD Type)
Temperature 1) Range without humidity (℃ / ℉) -5 to 85 / 23 to 185
without Light 0 to 85 / 32 to 185 with Light
with humidity (℃ / ℉) +15 to 85 / 59 to 185 with Light
Fluctuation 1) (±℃ / ℉) at 40℃ / 60%RH 0.3 / 0.55 0.3 / 0.55
Variation 1) (±℃ / ℉) at 40℃ / 60%RH 0.5 / 0.9 0.7 / 1.3
Time Heating 25min (20℃ → 85℃) 30min (20℃ → 85℃)
Cooling 35min (20℃ → -5℃) 40min (20℃ → -5℃)
Humidity Range (%RH) 20 to 85
※ See page 231 for more detailed humidity range check.
Fluctuation 2) (±%RH) at 60%RH / 40℃ 3
Variation 2) (±%RH) at 60%RH / 40℃ 5
Light source (ICH Q1B option 2) Cool white 3) 6,000 lux 6,500 lux
Ultraviolet-A 3) 4.5 W/㎡ 5 W/㎡
Light uniformity VIS. : ±10%UVA : ±15% VIS. : ±15%UVA : ±15%
Typical time required to reach ICH
Recommendation of 1.2 million lux-hr
≒ 200Hr ≒ 184Hr
Typical time required to reach ICH
recommendation of 200 W-hr/m2
≒ 50Hr ≒ 40Hr
Refrigeration System Air - cooled
Refrigerant R- 404A
Water tank Capacity (L / cu ft) 15 / 0.53
Water quality pH6.2 ~ 7.2, Electrical conductivity 20㎲ / cm to below
No. of wire shelves (standard / max.) 2 / 8 2 / 17
Distance of between shelves (mm / inch) 60 / 2.4 60 / 2.4
Max. load per shelf (kg / lbs) 25 / 55.1 40 / 88.2
Permitted total load (kg / lbs) 75 / 165.3 100 / 220.5
Dimension (W×D×H) Interior (mm / inch) 750×650×650 / 29.5×25.6×25.6 750×880×1160 / 29.5×34.6×45.7
Exterior (mm / inch) 1130×985×1520 / 44.5×38.8×59.8 1220×1215×1965 / 48×47.8×77.4
Net weight (kg / lbs) 280±10 / 617±22 400±10 / 882±22
Cable port Basically one hole provided / Ø 50mm (2”),
Optionally max. two holes available / Ø 50 or 80mm (2 or 3.2”)
Interface port Basically RS-232C, [RS-485 : optional]
Electrical requirements AC230V, 1ph, 60Hz 14.7 A 23.5 A
Cat.No. AAHC1005K AAHC1015K
AC230V, 1ph, 50Hz 14.7 A 23.5 A
Cat.No. AAHC1005K AAHC1015K

1) All specifications are under ambient temperature 20℃ (68℉), No load.
2) Technical data according to DIN 12880, IEC 60068.
3) The value is measured on the center of chamber at the point of vertical direction.

     

for Floor Standing Chambers

Accessory check list□ Standard     ○ Optional

Description Models
TH-G TH-I TH-KH TH-TG TH-ICH TH-CR
Recorder (6 points)
Recorder (digital, 6 channels)
interface converter RS-485C → 232C included a cable (5m / 16.4ft)
Interface cable (5m / 16.4ft)
Warning signal lamp
Inner glass door -
Viewing window -
Wire shelf
Perforated shelf
Cable port (Ø 50mm / 2”)
Cable port (Ø 80mm / 3.2”)
Temperature sensor (RTD type)
Humidity sensor
Fluorescent lamp (Cool White) - - - - -
UVA lamp - - - - -
UV sensor - - - - -
Illumination Sensor - - - - -
HEPA filter - - - - -
ULPA filter - - - - -
Water cartridge tank (Water Container) -
Water purifier
Direct water system

1) 80mm cable access hole is NOT available for 25L chamber.

Ordering information

Cat. No. Description Suitable for
AAA8T500 Recorder (6 points) All models
AAA8T505 Recorder (digital, 6 channels) All models
AAA8T540 interface converter RS-485C →
232C included a cable (5m / 16.4ft)
All models
AAA8T542 Interface cable (5m / 16.4ft) All models
AAA80550 Warning signal lamp All models
AAA81552 Inner glass door TH-G/I/KH-180
AAA81551 TH-G/I/KH-300, 408, CR-270
AAA81550 TH-G-800, 1000
AAAC2501 TH-TG-180
AAAC2502 TH-TG-300, 408
AAAC2503 TH-TG-800, 1000
AAA81554 TH-ICH-300
AAA81555 TH-ICH-800
AAA8T610 Cable port (Ø 50mm / 2”) All models
AAA8T611 Cable port (Ø 80mm / 3.2”) All models
00CFA0001185 Temperature sensor (RTD type) All models
00CFA0007113 Humidity sensor All models
00RTD0001190 Fluorescent lamp (cool white) TH-ICH-300
00RTD0001191 TH-ICH-800
00RTD0001188 UVA lamp TH-ICH-300
00RTD0001189 TH-ICH-800
AAA80680 THE-680 UV sensor TH-ICH-300/800
AAA80681 THE-681 Illumination sensor TH-ICH-300/800
AAA80661 Door lock device TH-ICH-300/800
00EDA0009184 HEPA filter TH-CR-270
00EDA0009175 ULPA filter TH-CR-270
AAA80622 Water cartridge tank All models
A
Cat. No. Description Suitable for
AAA8T621 Water purifier All models
AAA80620 Direct water system All models
00EDA0008212 Wire shelf TH-G/I/KH-180
00EDA0008213 TH-G/I/KH-300
00EDA0008214 TH-G/I/KH-408
00EDA0008215 TH-G-800
00EDA0008216 TH-G-1000
00RTD0001302 TH-TG-180
00RTD0001303 TH-TG-300
00RTD0001300 TH-TG-408
00RTD0001304 TH-TG-800
00RTD0001301 TH-TG-1000
00RTD0001305 TH-G/TG-1500
00RTD0001196 TH-ICH-300
00RTD0001198 TH-ICH-800
00STT0001040 TH-CR-270
AAA80602-1 Perforated shelf TH-G/I/KH-180
AAA80602-2 TH-G/I/KH-300
AAA80602-3 TH-G/I/KH-408
AAA80602-4 TH-G-800
AAA80602-5 TH-G-1000
AAA80604-11 TH-TG-180
AAA80604-12 TH-TG-300
AAA80604-13 TH-TG-408
AAA80604-14 TH-TG-800
AAA80604-15 TH-TG-1000
AAA80604-16 TH-G/TG-1500
AAA80604-2 TH-ICH-300
AAA80604-4 TH-ICH-800
AAA80603-1 TH-CR-270
     

     

Related Products

Inquiry Form

  • Title (*)

    Position

  • First name (*)

    Last name (*)

  • Company (*)

  • Business type (*)

    Business division

  • Country

    City

  • E-Mail (*)

    Phone

  • Request Product (Model)

  • Your message

  Consent to use of data *
I consent to the processing of the data above for service communication with JEIO TECH.
I agree that JEIO TECH may collect, store, and use the data that I have provided.